Custom Page

▇ Parameter【R-Y、W-T】hot runner/preheat function


 

1. Press and hold "MODE" key 5 sec to enter  LEVEL 2

2. Set "Lock=1111"

3. Press and hold "MODE" key + "<" key 5 sec to enter  LEVEL 4

4. Set "St-5-3=1"

(Default 0000 was revised to 0100)

5. Press AUT key Back to LEVEL1

(Press and hold" MODE" key for 5 Back to LEVEL1)

6. Press and hold "MODE" key + "<" key 5 sec to enter  LEVEL 3

7. Set "r-Y=105" (reheating temperature)

8. Set "W-t=40" (preheat output limit the proportion of)

  Parameter W-t in programmable the use of wait function 

9. Press AUT key Back to LEVEL1

(Press and hold" MODE" key for 5 Back to LEVEL1)

10. SV>PV when turned on output

11. Temperature does not exceed 105 degrees when the output limit of 40%

      Temperature over 105 when open normally output

Temperature exceeds r-Y set value 0.1 degrees 

turn on automatic calculation