▇ Parameter【R-Y、W-T】hot runner/preheat function
1. Press and hold "MODE" key 5 sec to enter LEVEL 2
2. Set "Lock=1111"
3. Press and hold "MODE" key + "<" key 5 sec to enter LEVEL 4
4. Set "St-5-3=1"
(Default 0000 was revised to 0100)
5. Press AUT key Back to LEVEL1
(Press and hold" MODE" key for 5 Back to LEVEL1)
6. Press and hold "MODE" key + "<" key 5 sec to enter LEVEL 3
7. Set "r-Y=105" (reheating temperature)
8. Set "W-t=40" (preheat output limit the proportion of)
Parameter W-t in programmable the use of wait function
9. Press AUT key Back to LEVEL1
(Press and hold" MODE" key for 5 Back to LEVEL1)
10. SV>PV when turned on output
11. Temperature does not exceed 105 degrees when the output limit of 40%
Temperature over 105 when open normally output
Temperature exceeds r-Y set value 0.1 degrees
turn on automatic calculation